Temperature in buildings
Contents |
[edit] Introduction
Temperature is a measure of the average kinetic energy of molecules.
Average temperature relates to the overall movement of molecules in a substance or material. Temperature will tend to vary throughout a body depending on its heat exchange with its surroundings. Temperature can be expressed in degrees Celsius (°C), kelvin (°k) or Fahrenheit (°F), with Kelvin being the scientific measure. Celsius relates to the properties of water, where zero is freezing and 100 is steam.
Measuring temperature actually records the temperature of the sensor that is being used to carry out the measurement. As a consequence, different types of measurement have been developed to represent the temperature of different types of body. Some of these methods are described below.
[edit] Thermal comfort
Temperature can be a particularly important measure in the built environment when considering the thermal comfort of occupants and in the design of building services systems. As a consequence, many of the measures of temperature are intended to represent the thermal comfort of people, or some component of their thermal comfort. Thermal comfort is a complex science in its own right.
Making a building comfortable is not as simple as delivering an average internal air temperature of 21 °C throughout the year. Thermal comfort is dependent on a range of environmental factors in addition to air temperature, such as; air velocity, radiant temperature, relative humidity and the uniformity of conditions. It also depends on personal factors such as; clothing, metabolic heat, state of health, acclimatisation, expectations, and even access to food and drink.
BS EN ISO 7730 defines thermal comfort as '…that condition of mind which expresses satisfaction with the thermal environment.', ie the condition when someone is not feeling either too hot or too cold. The Health and Safety Executive suggest that an environment can be said to achieve 'reasonable comfort' when at least 80% of its occupants are thermally comfortable.
See thermal comfort for more information.
NB: Heat stress is a form of overheating that the occupants of a building may experience when the measures that their body uses to regulate internal temperature begin to fail. This can occur for example in buildings where an industrial process is being carried out, such as; smelting, brick-firing, cooking, and so on. See Heat stress for more information.
[edit] Measures of temperature
[edit] Dry-bulb temperature
Dry-bulb temperature (Tdb, DBT or Td), is a measure of air temperature. It is referred to as dry-bulb temperature because the thermometer bulb is dry and so the temperature recorded does not vary with the moisture content of the air. See dry-bulb temperature for more information.
[edit] Wet-bulb temperature
Wet-bulb temperature (Twb or Tw) is the temperature recorded by a thermometer that has its bulb wrapped in cloth and moistened with distilled water. See wet-bulb temperature for more information.
[edit] Wet-bulb globe temperature
Wet-bulb globe temperature (WBGT) is an index that is widely used for the assessment of heat stress. It combines wet-bulb temperature, dry-bulb temperature and globe temperature. See wet-bulb globe temperature and heat stress for more information.
[edit] Mean radiant temperature
Mean radiant temperature (MRT) is a measure of the average temperature of the surfaces that surround a particular point. If the point is exposed to the outside, this may include the sky temperature and solar radiation. See mean radiant temperature for more information.
[edit] Globe temperature
Globe temperature (or black-globe temperature) was introduced as a means of assessing the combined effects of radiation, air temperature and air velocity as they influence human comfort. It is measured using a globe thermometer, a hollow copper sphere painted matt back to absorb radiant heat with a temperature sensor at its centre. This can be used in conjunction with air temperature and air velocity to calculate mean radiant temperature. See globe temperature for more information.
[edit] Sling psychrometer
Sling psychrometers hold a wet-bulb thermometer and a dry-bulb thermometer. They can be used to determine the physical and thermal properties of moist air by using standard tables. See sling psychrometer for more information.
[edit] Operative temperature
Operative temperature (previously known as resultant temperature or dry resultant temperature, but renamed to align with ASHRAE and ISO standards) is a simplified measure of human thermal comfort derived from air temperature, mean radiant temperature and air speed. See operative temperature for more information.
[edit] Resultant temperature
A measure of thermal comfort now re-named 'operative temperature'. See operative temperature for more information.
[edit] Predicted mean vote
Predicted mean vote (PMV) is an empirical fit to the sensation of thermal comfort. It predicts the average vote of a large group of people on the a seven-point thermal sensation scale where +3 is hot and -3 is cold. See predicted mean vote for more information.
[edit] Running mean temperature
An exponentially-weighted outside running mean temperature can be used to account for the time-dependency of thermal comfort. Adaptive comfort theory suggests that the occupants of a building will adapt to their environment over time, adjusting clothing, modifying behaviour and so on and so might accept conditions that would otherwise have been predicted to be unsatisfactory. See running mean temperature for more information.
[edit] Accumulated temperature
Median accumulated temperature above 0°C from January to June which gives a measure of heat energy input and soil drying potential and correlates with crop growth and yield.
[edit] Related articles on Designing Buildings
- Accumulated temperature.
- Dry-bulb temperature.
- Excess cold.
- Globe temperature.
- Human comfort in buildings.
- Mean radiant temperature.
- Operative temperature.
- Overheating.
- Overheating - assessment protocol.
- Predicted percentage dissatisfied.
- Predicted mean vote.
- Psychometric chart.
- Reflected apparent temperature.
- Running mean temperature.
- Sky temperature.
- Sling psychrometer.
- Temperature factor.
- Thermal comfort.
- Thermal environment.
- Thermal indices.
- Thermodynamic temperature.
- Thermostat.
- Wet-bulb temperature.
- Wet-bulb globe temperature.
Featured articles and news
CIOB launches global mental health survey
To address the silent mental health crisis in construction.
New categories in sustainability, health and safety, and emerging talent.
Key takeaways from the BSRIA Briefing 2024
Not just waiting for Net Zero, but driving it.
The ISO answer to what is a digital twin
Talking about digital twins in a more consistent manner.
Top tips and risks to look out for.
New Code of Practice for fire and escape door hardware
Published by GAI and DHF.
Retrofit of Buildings, a CIOB Technical Publication
Pertinent technical issues, retrofit measures and the roles involved.
New alliance will tackle skills shortage in greater Manchester
The pioneering Electrotechnical Training and Careers Alliance.
Drone data at the edge: three steps to better AI insights
Offering greater accuracy and quicker access to insights.
From fit-out to higher-risk buildings.
Heritage conservation in Calgary
The triple bottom line.
College of West Anglia apprentice wins SkillELECTRIC gold.
Scottish government launch delivery plan
To strengthen planning and tackle the housing emergency.
How people react in ways which tend to restore their comfort.
Comfort is a crucial missing piece of the puzzle.
ECA launches Recharging Electrical Skills Charter in Wales
Best solutions for the industry and electrical skills in Wales.
New homebuilding skills hub launch and industry response
Working with CITB and NHBC to launch fast track training.